AC, furnace, attic duct-work, gas line, and water heater
Thank you for your time and support we will be more than happy to help our valuable customers like you
Thank you for your time and support we will be more than happy to help our valuable customers like you
Thank you for your time and support we will be more than happy to help our valuable customers like you
I would like to have my explanation.
1. I gave him my estimate and after 5 days he called to hire me. Therefore, it seems as though he had sufficient time to call others and shop around.
2. As always I included my job details on my quote, and it did not include the vent cover and thermostat since he did not initially request them. Therefore, the cost for those two items were added as per hi request. I even waived my own cost and labour for those added jobs of changing thermostat wire from furnace to thermostat.
3. This was a 2 days job, and we were present at the job site on the agreed time both days.
4. When i was sweeping the floor, as I always do after the job, I was offered to use the central vacuum instead to clean the dust by the wife.
5. We took away all the big garbage bags by my car as we always do. However, I made the mistake of putting some ounces of garbage into the bin.
6. We had all the tools and equipments in the main floor. The only tools we used from the house owner was the ladder in the basement which I had his wife permission and I just used it for one hour and placed back.
7. Also, he owed me $200 and never picked up his phone to make arrangements for due ballance or listen to my explanation and offer for reconciliation after his complain.
I value educating the house owners on my job, especially those interested in learning. I answered all his questions and explained what I was doing, perhps except for when I was on top of the ladder and focused on the detailed work.
I apologize in any case and thank you for your business.
GTA Heating & A/C INC
Installation of a Central A/C Unit
On Thursday April 19/2012 we had the appointment to check the functioning of 1.5 Ton Carrier Air Conditioner with 2 Ton Coil on your 1200 Square Feet home.
We checked some data together and you did confirm it, however you did not know what those data means, so by E-mailing you have a chance to discuss with other experts.
High side pressure at beginning was 660 PSI (As you said two companies try to work on the unit, and I don’t know why they inject extra R-410 in the unit), so we had to reclaim the R-410 and charge the unit with fresh refrigerant.
Now High Side Pressure is 265 PSI
Sub Cooling Require is 10 F
High Side Temperature is 75 F
Tolerance accepted is + , - 3 F
High Side Temperature is 78 F
Low Side pressure is 110 PSI
Low Side Temperature is 53.4 F
Free Air Temperature is 73 F
Air coming through the register 58 F
Base on Manufacture Data Chart, unit works perfectly, but as you know you should take care of some others issues in your home, such as:
First, duct work, because there is no enough air flow in half side of the house.
Second, there is no enough Air Return suction, on second level of the house.
Third, you should do some things to eliminate the direct sun lights to the house. Also all windows suppose to be closed when A/C is working. So as our valuable customer we are here to help you to have a comfort air temperature in your home during the summer.
Thanks for your business.